DIGIMAX FS 8-Channel Preamplifier with 24-bit/96k ADAT I/O (dual SMUX) User’s Manual Version 1.0 © 2006, PreSonus Audio Electronics, Incorpo
APPLICATIONS device to the first SMUX source device via BNC, and to sync the first SMUX source device to the DigiMax FS via BNC (or optical) and desig
APPLICATIONS BNC Sync Many engineers prefer to take care of word clock and audio separately from each other, and you will find BNC cables used to del
APPLICATIONS Multiple Digital Devices In cases where multiple digital devices are in use, such as multiple DigiMax FS units in conjunction with a digi
APPLICATIONS control panel software application and/or your multi-channel recording application. Using the DigiMax FS with Pro Tools Below are instruc
APPLICATIONS 2.5 Hook Up Diagram 14
3 TECHNICAL 3.1 Technical Specifications Microphone Preamp (XLR Balanced) All measurements Microphone Input to Direct Output Frequency Response (+0,-
TECHNICAL Digital Audio ADC Dynamic Range (Awtd, 48KHz Sample Rate) 107dB DAC Dynamic Range (Awtd, 48KHz Sample Rate) 110dB Bit Depth 24 Reference
WARRANTY PreSonus Limited Warranty PreSonus Audio Electronics Inc. warrants this product to be free of defects in material and workmanship for a per
1 Overview 1.1 Introduction 4 1.2 Front Panel 5 1.3 Back Panel 6 2 Applications 2.1 Dynamic Microphones 8 2.2 Phantom Powered Microphones
OVERVIEW 1.1 Introduction Thank you for purchasing the PreSonus DigiMax FS™ 8-Channel Preamplifier with 24-bit/96k ADAT I/O (dual SMUX). The DIGIMAX
OVERVIEW 1.2 Front Panel Class A Mic Pre. Each channel of your DigiMax FS contains a Class A discrete differential input amplifier, providing ultra
OVERVIEW 1.3 Back Panel Note that all inputs and outputs can be use simultaneously. Inserts. The DigiMax FS features insert points for each input. (
OVERVIEW BNC In and Out. The BNC input allows an external clock to be connected to the DigiMax FS as a slave. The BNC output allows the DigiMax FS to
2 APPLICATIONS 2.1 Dynamic Microphones Dynamic microphones are characterized by lower output levels. Hence, more gain is needed to amplify a dynamic m
APPLICATIONS SMUX SMUX, a newer generation of optical light pipe technology, supports sample rates up to 96k and utilizes two optical cables for chan